Advanced Table Top MALDI LaserToF

MALDI LaserToF LT2 Plus

SAI's LaserToF LT2 Plus is a completely automated, compact and versatile matrix assisted laser desorption ionization time of flight (MALDI-TOF) mass analyser.  The instrument is designed for the rapid and accurate analysis of a wide range of biomolecules such as bacteria, peptides, proteins and oligonucleotides. The LT2 Plus is also suitable for the analysis of industrial polymers as used in the petroleum and chemical additive industries.

  • Linear MALDI-ToF
  • Resolution: > 500 FWHM
  • Mass accuracy: >500 ppm RMS (external calibration),
  • > 100 ppm (internal calibration)
  • Pulsed Extraction
  • Simple operation
  • Sample viewing camera
  • Attractive Pricing
  • Small Footprint

LT2

For more information click here.

MALDI LaserToF LT3 Plus

SAI's LaserToF LT3 Plus is a completely automated, compact and versatile matrix assisted laser desorption ionization time of flight (MALDI-TOF) mass analyzer.  The LT3 has the same features as the LT2 but at a higher resolution due to its reflectron mode.  The instrument is designed for the rapid and accurate analysis of a wide range of biomolecules such as peptides, proteins and oligonucleotides. The LT3 Plus is also suitable for the analysis of industrial polymers as used in the petroleum and chemical additive industries.

  • Reflectron & Linear MALDI-ToF
  • 96 well 1/4 Microtitre plate
  • Resolution: > 20,000 FWHM (Reflectron), > 2,500 FWHM (Linear)
  • Mass accuracy: 100 ppm RMS (external calibration),< 20 ppm (internal calibration)
  • Pulsed Extraction
  • Simple operation
  • Sample viewing camera
  • Attractive Pricing
  • Small Footprint

LT3

For more information click here.

MALDI ToF-ToF - LaserToF TT

LaserToF TT is a Research Grade MALDI-MS/ MS instrument, incorporating some of the most advanced performance and design features of any mass spectrometer. It offers rapid and accurate single scan seamless MS/MS analysis. The design combines high resolution peptide mass fingerprinting and peptide sequencing by uni or bi molecular fragmentation. The instrument is equipped with a 2D sample stage (including 96/384/1536-well format) for high throughput automated analysis.

  • < 100 Attomole Sensitivity
  • Resolution: > 20,000 FWHM (Reflectron), > 4000 FWHM (Linear)
  • Mass accuracy: 50 ppm RMS (external calibration), < 5 ppm (internal calibration)
  • Novel “ZOOM” Lens
  • Collision Cell
  • Post Source Decay (PSD)
  • Full Proteomics Software
  • Full Imaging Capability
  • 337 nm UV (nitrogen) Laser, optional Nd/YAG Laser

TT

For more information click here.

© 2014 - RGS Scientific | Call: 972-503-0686 | info@rgsscientific.com | Sitemap