Kronus GC ToF-MS

Kronus turnkey GCMS system


The first of a new generation of GCMS instrumentation, Kronus represents a new concept in design of time of flight analyzer combined with a fully integrated gas chromatograph in a compact benchtop instrument. The mass spectrometer is based on a novel combination of energy filter preceding a time of flight analyzer to give the best possible sensitivity and dynamic range in all GCMS ionization modes. This revolutionary concept brings all the advantages of time of flight technology to GCMS in a small affordable package.

  • Complete auto and manual tune modes
  • High sensitivity design with very high duty cycle
  • Robust design incorporating an energy filter to enhance mass transmission and prevent direct contamination of the mass analyser giving maintenance free lifetime performance
  • Full Scan and Single Ion Monitoring (SIM) modes of mass analysis within the same scan
  • Mass range from 2 to 2000Da
  • High stability and automatic calibration
  • Scan Rate: Up 100 scans /sec written to disk
  • Resolution: better than 1000 at m/z 500(FWHM)

Kronus1

For more information click here.


Stand-Alone ToF-MS For Existing GC systems

The Kronus SA Time of Flight analyzer is also available as a stand-alone unit. This instrument can be fitted to a wide range of GCs including existing systems that may currently be in use with a FID. The ToF unit has also been designed to operate with GCxGC systems and comes complete with all the necessary hardware to enable simple interfacing. The system comes with a reference inlet, EI ion source and heated GC transfer line as standard.

  • Complete auto and manual tune modes
  • High sensitivity design with very high duty cycle
  • Robust design incorporating an energy filter to enhance mass transmission and prevent direct contamination of the mass analyzer giving maintenance free lifetime performance
  • Full Scan and Single Ion Monitoring (SIM) modes of mass analysis within the same scan
  • Mass range from 2 to 1200 Da
  • High stability and automatic calibration
  • Scan Rate: Up 100 scans /sec written to disk
  • Resolution: better than 1200 at m/z 500(FWHM)


Kronus GCxGC ToF-MS

SAI, Ltd. now offers a comprehensive GC ToF  ( GCxGC-ToF ) system based on the Kronus ToF analyzer.  Because GCxGC is both a qualitative and quantitative technique, most GC applications can be accomplished using GCxGC.

Applications include:

    • Petroleum Liquids
    • Environmental Forensics
    • PCBs/Dioxins/Pesticides
    • Flavors & Fragrances
    • Air Toxics
    • Industrial Process Diagnosis
    • Pyrolysates (Fire Debris, Tobacco)
    • Catalysis
    • Soils and Sediments
    • Chemical Warfare Agents

© 2014 - RGS Scientific | Call: 972-503-0686 | info@rgsscientific.com | Sitemap